Seojin
Mini Float type level switch (SOL)
Operating Principle This is designed to control the level in container by using reed switches and magnet. When reed switches built in inside pipe are contacted by magnet, contact point outputs and the level is controlled.
Range ㆍSTD : 57mm ㆍOptional : 300mm
Process temperature ㆍSOL-5 : -10°C∼100°C ㆍSOL-2B/2P/3 : -10°C∼90°C
Process pressure ㆍSOL-5/2B : Max.10㎏/㎠ ㆍSOL-2P/3 : Max.5㎏/㎠
Features ㆍCompact size ㆍLow cost ㆍReliability/Long switch life ㆍUsable with wide range of liquids ㆍEasy installation
Output ㆍSTD : 1 point ㆍOptional : 2∼4 point ㆍContact Rating : 0.5A 300 VAC / 0.5A 300 VDC
Application ㆍCoffee slot machine ㆍHumidifier ㆍMedical equipment ㆍVending machines ㆍAnalyzers ㆍAir conditioners ㆍIce makers ㆍAgricultural machines ㆍEngines &, Hydraulic equipment
................................................................................................................................................................................................................................................................................................................................................
Magnetic Float Type Level Switch (SHM-2000)
Operating Principle The range of linear core movement is determined by selecting the rotating angle of the float and lengths, L1 and L2, to actuate the micro-switch, which controls the power to pump or drain equipment.
Range ㆍSTD : 188mm
Process temperature ㆍSTD : -25°C∼150°C ㆍOptional : -25°C∼350°C
Process pressure ㆍMax.100㎏/㎠
Features ㆍLiquid level control for high temperature and/or high ㆍpressure systems ㆍFor control of levels in turbine service tanks of electric ㆍpower plants ㆍFor control of boiler feed water and other pressure ㆍvessels ㆍFor control of levels in oil tanks and petro-chemical ㆍprocessing plants ㆍA variety of mounting chambers are available ㆍSimple installation ㆍSelectable of installation chambers ㆍAvailable explosion proof
Output ㆍSTD : 1 SPDT ㆍOptional : 1 DPDT ㆍContact Rating : 5A 250 VAC
Application ㆍ High pressure and temperature boiler tanks of power plant ㆍ Waste water or clean water tank ㆍ Various chemical tank ㆍ Fuel & oil tank ㆍ Beverage tank ㆍ etc.
................................................................................................................................................................................................................................................................................................................................................
Float Type Level Transmitter (ST- 600)
Operating Principle When measuring material rises and falls in tank, reed switches which ar built in inside pipe have contact point because magnet installed inside float and resistors connected to reed switches ake resistance change in proportion to level variation.
Range ㆍMax. 5.9m
Process temperature ㆍ STD : -10°C∼60°C ㆍOptional : -10°C∼100°C
Process pressure ㆍSUS304/316 : Max. 10㎏/㎠ ㆍPVC/PTFE : Max. 2㎏/㎠
Features ㆍVery low cost compared to other type level equipment ㆍRemote and local display ㆍApplicable to various liquid when the probe material is changed ㆍItems 1~3 are same with the left ㆍRemote display and control is possible ㆍAvailable explosion proof Output ㆍ 4∼20mA DC Power specifications 24 VDC
Application ㆍMunicipal water, clean water industrial water, waste water, drinking water ㆍLiquid tank of ship ㆍLPG, chemical, oil, acid, solvent ㆍetc.
................................................................................................................................................................................................................................................................................................................................................
Displacement Type Level Transmitter (SDT-420)
Operating Principle The variable buoyancy force exerted on a stationary displacer immersed in a liquid is transferred to a strain gauge pressure transducer through a torque tube. The pressure transducer thus turns according to the changing liquid levels into proportional electric current. The operating buoyancy of the displacer varies with liquids since buoyancy is a function of the liquid density, and the operating buoyancy is maintained by adjusting the balance spring.
Range ㆍ350∼2000mm
Process temperature ㆍ Max. 450°C
Process pressure ㆍMax. 100㎏/㎠
Features ㆍMaximum application pressure 100㎏/㎠ ㆍMaximum applicable temperature 450°C ㆍAutomatically sets zero and span ㆍThe span can be set at any actual liquid level ㆍAccurate to ± 0.2% F.S ㆍContinuous self-diagnosis is available ㆍThe transmitter can be calibrated without removing the cover ㆍCorrosion resistant material is available ㆍLevel sensing point can be easily changed ㆍHART communication ㆍSMART type ㆍAvailable explosion proof Output ㆍ 4∼20mA DC
Power specifications ㆍ 15∼30 VDC
Application ㆍHigh pressure and temperature boiler tanks of power plant ㆍ Waste water or clean water tank ㆍVarious chemical tank ㆍ Fuel & oil tank ㆍ Beverage tank ㆍetc.
................................................................................................................................................................................................................................................................................................................................................
The range of linear core movement is determined by selecting the rotating angle of the float and lengths, L1 and L2, to actuate the micro-switch, which controls the power to pump or drain equipment.
|